1.1 |
Date updated: |
Jun 04, 2023 |
1.2 |
Vessel's name (IMO number): |
Ardmore Endurance (9654567) |
1.3 |
Vessel's previous name(s) and date(s) of change: |
Front Avon (Aug 31, 2016) |
1.4 |
Date delivered / Builder (where built): |
Dec 04, 2013 / STX Offshore & Shipbuilding Jinhae - Korea |
1.5 |
Flag / Port of Registry: |
Marshall Islands / Majuro |
1.6 |
Call sign / MMSI: |
V7AY7 / 538005095 |
1.7 |
Vessel's contact details (satcom/fax/email etc.): |
Tel: +1 64 6466 9794 Fax: Email: master.aendurance@skyfile.com |
1.8 |
Type of vessel (as described in Form A or Form B Q1.11 of the IOPPC): |
Oil Tanker |
1.9 |
Type of hull: |
Double Hull |
1.10 |
Registered owner - Full style: |
BLASKET SHIPCO LLC The Trust Company of the Marshall Islands, Inc.Trust Company Complex Ajeltake Road, Ajeltake IslandMajuro, Republic of the Marshall Islands MH 96960 Marshall Islands Tel: +86 21 6106 1534 Telex: NA |
1.11 |
Technical operator - Full style: |
Anglo Ardmore Ship Management Limited 17/F Kingston International Centre
19 Wang Chiu Road Kowloon Bay,
Kowloon
Hong Kong
Hong Kong Tel: +852 3940 7000 Fax: +852 2861 2419 Telex: NA Email: vetting@angloardmore.com Web: NA Company IMO#: 5993395 |
1.12 |
Commercial operator - Full style: |
Ardmore Maritime Services (Asia) Pte Ltd 137 Telok Ayer Street
#08-01
Singapore Singapore Tel: +353212409500 Fax: +353212409512 Telex: NA Email: commercialoperations@ardmoreshipping.com Web: www.ardmoreshipping.com |
1.13 |
Disponent owner - Full style: |
Ardmore MR Pool LLC Trust Company Complex, Ajeltake Road, Ajeltake Island, Majuro, MH 96960, Marshall Islands Tel: +65 63299400 Fax: N/A Telex: N/A Email: commercialoperations@ardmoreshipping.com Web: www.ardmoreshipping.com |
1.14 |
P & I Club - Full Style: |
Tower Bridge Court
226 Tower Bridge Road
London
SE1 2UP Tel: +44 20 7716 6000 Fax: +44 20 7716 6100 Telex: NA Email: mail@westpandi.com Web: westpandi.com |
1.15 |
P & I Club pollution liability coverage / expiration date: |
1,000,000,000 US$ |
Feb 20, 2024 |
1.16 |
Hull & Machinery insured by - Full Style: (Specify broker or leading underwriter) |
Ed Broking LLP 2 Minster Court
London EC3R 7PD
UK Tel: +44 20 7626 3711 Fax: +44 20 7283 4175 |
1.17 |
Hull & Machinery insured value / expiration date: |
US$ (Contact Owners for Details) |
Jul 01, 2023 |
1.18 |
Classification society: |
|
1.19 |
Class notation: |
1A1 Tanker for Chemicals and Oil ESP CSR SPM E0VCS-2B Clean BWM-E(s) Coat-PSPC(B) BIS ETC TMON |
1.20 |
Is the vessel subject to any conditions of class, class extensions, outstanding memorandums or class recommendations? If yes, give details: |
No Nil
|
1.21 |
If classification society changed, name of previous and date of change: |
, Not Applicable |
1.22 |
Does the vessel have ice class? If yes, state what level: |
No, N/A |
1.23 |
Date / place of last dry-dock: |
Nov 22, 2018 / Chengxi Shipyard Jiangyin, China |
1.24 |
Date next dry dock due / next annual survey due: |
Dec 04, 2023 |
Dec 04, 2023 |
1.25 |
Date of last special survey / next special survey due: |
Nov 22, 2018 |
Dec 04, 2023 |
1.26 |
If ship has Condition Assessment Program (CAP), what is the latest overall rating: |
No, |
1.27 |
Length overall (LOA): |
183 m |
1.28 |
Length between perpendiculars (LBP): |
175.90 m |
1.29 |
Extreme breadth (Beam): |
32.20 m |
1.30 |
Moulded depth: |
19.10 m |
1.31 |
Keel to masthead (KTM)/ Keel to masthead (KTM) in collapsed condition, if applicable: |
49.477 m |
m |
1.32 |
Distance bridge front to center of manifold: |
56.29 m |
1.33 |
Bow to center manifold (BCM) / Stern to center manifold (SCM): |
91.86 m |
91.14 m |
1.34 |
Parallel body distances: |
Lightship |
Normal Ballast |
Summer Dwt |
Forward to mid-point manifold: |
27.71 m |
35.86 m |
35.86 m |
Aft to mid-point manifold: |
22.70 m |
41.25 m |
50.92 m |
Parallel body length: |
50.41 m |
77.11 m |
86.78 m |
1.35 |
Net Tonnage: |
13,738 |
1.36 |
Gross Tonnage / Reduced Gross Tonnage (if applicable): |
29,993 |
23,712 |
1.37 |
Suez Canal Tonnage - Gross (SCGT) / Net (SCNT): |
30,539.98 |
25,707.92 |
1.38 |
Panama Canal Net Tonnage (PCNT): |
24,835 |
1.39 |
Loadline |
Freeboard |
Draft |
Deadweight |
Displacement |
Summer: |
6.677 m |
12.436 m |
44,994.20 MT |
56,091.30 MT |
Winter: |
6.677 m |
12.436 m |
44,994.20 MT |
56,091.30 MT |
Tropical: |
6.677 m |
12.436 m |
44,994.20 MT |
56,091.30 MT |
Lightship: |
16.20 m |
2.92 m |
|
11,097.10 MT |
Normal Ballast Condition: |
11.19 m |
7.93 m |
22,508.50 MT |
33,605.60 MT |
Segregated Ballast Condition: |
11.30 m |
7.81 m |
22,455.60 MT |
33,038.50 MT |
1.40 |
FWA/TPC at summer draft: |
272.30 mm |
51.50 MT |
1.41 |
Does vessel have multiple SDWT? If yes, please provide all assigned loadlines: |
Yes 49465.8 MTS / 44999 MTS / 39997.4 MTS |
1.42 |
Constant (excluding fresh water): |
200 MT |
1.43 |
What is the company guidelines for Under Keel Clearance (UKC) for this vessel? |
1.Pilotage:10% of Max Static Draft + Squat at Transit Speed + Variables
2.Coastal Waters:20% of Max Static Draft + Squat at Transit Speed + Variables
3. Open Waters:50% of Max Static Draft + Squat at Transit Speed + Variables
4.At Berth: 1.5% of Vessel's Extreme Breadth or 0.3m, whichever is greater + Variables.
5.SPM or CBM: not less than 20% of vessels static draft + Variables
|
1.44 |
What is the max height of mast above waterline (air draft) |
Full Mast |
Collapsed Mast |
Summer deadweight: |
37.041 m |
0 m |
Normal ballast: |
39.667 m |
0 m |
Lightship: |
46.559 m |
0 m |
|
2.1 |
Safety Equipment Certificate (SEC): |
Nov 13, 2021 |
Nov 20, 2022 |
Jan 13, 2021 |
Dec 04, 2023 |
2.2 |
Safety Radio Certificate (SRC) |
Nov 13, 2021 |
Nov 20, 2022 |
|
Dec 04, 2023 |
2.3 |
Safety Construction Certificate (SCC): |
Nov 13, 2021 |
Nov 20, 2022 |
Jan 13, 2021 |
Dec 04, 2023 |
2.4 |
International Loadline Certificate (ILC): |
Nov 13, 2021 |
Nov 20, 2022 |
|
Dec 04, 2023 |
2.5 |
International Oil Pollution Prevention Certificate (IOPPC): |
Nov 20, 2022 |
Nov 20, 2022 |
Jan 13, 2021 |
Dec 04, 2023 |
2.6 |
International Ship Security Certificate (ISSC): |
Sep 22, 2021 |
Not Applicable |
|
Dec 20, 2026 |
2.7 |
Maritime Labour Certificate (MLC): |
Sep 22, 2021 |
|
|
Dec 20, 2026 |
2.8 |
ISM Safety Management Certificate (SMC): |
Sep 22, 2021 |
|
|
Dec 20, 2026 |
2.9 |
Document of Compliance (DOC): |
Sep 02, 2021 |
Aug 31, 2022 |
Not Applicable |
Oct 23, 2026 |
2.10 |
USCG Certificate of Compliance (USCGCOC): |
Aug 03, 2020 |
Jul 30, 2021 |
|
Aug 03, 2022 |
2.11 |
Civil Liability Convention (CLC) 1992 Certificate: |
Feb 20, 2023 |
|
|
Feb 20, 2024 |
2.12 |
Civil Liability for Bunker Oil Pollution Damage Convention (CLBC) Certificate: |
Feb 20, 2023 |
|
|
Feb 20, 2024 |
2.13 |
Liability for the Removal of Wrecks Certificate (WRC): |
Feb 20, 2023 |
|
|
Feb 20, 2024 |
2.14 |
U.S. Certificate of Financial Responsibility (COFR): |
Aug 29, 2022 |
|
|
Aug 29, 2025 |
2.15 |
Certificate of Class (COC): |
Nov 20, 2022 |
Nov 20, 2022 |
Jan 13, 2021 |
Dec 04, 2023 |
2.16 |
International Sewage Pollution Prevention Certificate (ISPPC): |
Nov 13, 2021 |
|
|
Dec 04, 2023 |
2.17 |
Certificate of Fitness (COF): |
Nov 13, 2021 |
Nov 20, 2022 |
Jan 13, 2021 |
Dec 04, 2023 |
2.18 |
International Energy Efficiency Certificate (IEEC): |
Nov 13, 2021 |
|
|
|
2.19 |
International Air Pollution Prevention Certificate (IAPPC): |
Nov 13, 2021 |
Nov 13, 2021 |
Jan 13, 2021 |
Dec 04, 2023 |
2.20 |
Owner warrant that vessel is member of ITOPF and will remain so for the entire duration of this voyage/contract: |
Yes |
2.21 |
Does vessel have in place a Drug and Alcohol Policy complying with OCIMF guidelines for Control of Drugs and Alcohol Onboard Ship? |
Yes (Last Un-announced Shore Test carried out Feb 07,2023 at San Lorenzo) |
2.22 |
Is the ITF Special Agreement on board (if applicable)? |
Yes |
2.23 |
ITF Blue Card expiry date (if applicable): |
Aug 30, 2024 |
|
3.1 |
Nationality of Master: |
Indian |
3.2 |
Number and nationality of Officers: |
11 |
Indian |
3.3 |
Number and nationality of Crew: |
11 |
Indian |
3.4 |
What is the common working language onboard: |
English |
3.5 |
Do officers speak and understand English: |
Yes |
3.6 |
If Officers/Crew employed by a Manning Agency - Full style: |
Officers: Anglo Ardmore Ship Management Limited 17/F Kingston International Centre
19 Wang Chiu Road Kowloon Bay,
Kowloon
Hong Kong Tel: +852 3940 7000 Fax: +852 2861 2419 Telex: NA Email: operations@angloardmore.com Web: NA
Crew: same as for Officers 17/F Kingston International Centre
19 Wang Chiu Road Kowloon Bay,
Kowloon
Hong Kong Tel: +852 3940 7000 Fax: +852 2861 2419 Email: operations@angloardmore.com Web: NA |
|
4.1 |
Has the vessel Operator submitted a Vessel Spill Response Plan to the US Coast Guard which has been approved by official USCG letter? |
Yes |
4.2 |
Qualified individual (QI) - Full style: |
O'Brien's Oil Pollution Service O'Briens Response Management Inc
New Jersey Office
103 Morgan Lane
Suite 103, Plainsboro, NJ 08536
USA Tel: +1 281 606 4818 Fax: +1-985-781-0580 Telex: 49617361 OOPS UI Email: commandcenter@obriensrm.com Web: NA |
4.3 |
Oil Spill Response Organization (OSRO) - Full style: |
National Response Corporation 3500 Sunrise Highway
Suite T103 Great River
NY 11739
USA Tel: +1-631-224-9141 Fax: +1-631-224-9086 Telex: NA Email: iocdo@nrcc.com Web: NA |
4.4 |
Salvage and Marine Firefighting Services (SMFF) - Full Style: |
RESOLVE MARINE GROUP, INC 1510 SE 17th Street, Suite 400
Fort Lauderdale, FL 33316 Tel: +1 954 764 8700 Fax: +1-954-764-8724 Email: opa90@resolvemarine.com Web: www.resolvemarine.com |
|
5.1 |
Is the vessel operated under a Quality Management System? If Yes, what type of system? (ISO9001 or IMO Resolution A.741(18) as amended): |
Yes ISO 9001:2008 |
5.2 |
Can the ship comply with the ICS Helicopter Guidelines? |
Yes |
5.2.1 |
If Yes, state whether winching or landing area provided: |
Winching |
5.2.2 |
If Yes, what is the diameter of the circle provided: |
10 m |
|
6.1 |
Tank Coating |
Coated |
Type |
To What Extent |
Anodes |
Cargo tanks: |
Yes |
Interline 994, phenolic Epoxy |
Whole Tank |
No |
Ballast tanks: |
Yes |
Epoxy |
|
Yes |
Slop tanks: |
Yes |
Phenolic Epoxy |
Whole Tank |
No |
|
7.1 |
Pumps: |
No. |
Type |
Capacity |
At What Head (sg=1.0) |
Ballast Pumps: |
2 |
FRAMO SUBMERGED CENTRIFUGAL |
700 m3/hr |
25 m |
Ballast Eductors: |
1 |
Water Driven |
100 m3/hr |
25 m |
|
8.1 |
Is vessel fitted with centerline bulkhead in all cargo tanks? If Yes, solid or perforated: |
Yes, Solid |
8.2 |
Number of cargo tanks and total cubic capacity (98%): |
12 |
51,392.73 m3 |
8.2.1 |
Capacity (98%) of each natural segregation with double valve (specify tanks): |
As per Company policy 98%
Seg No.1W: 5861.641 cbm
Seg No.2W: 9079.389 cbm
Seg No.3W: 9505.081 cbm
Seg No.4W: 9513.304 cbm
Seg No.5W: 9507.506 cbm
Seg No.6W: 7925.808 cbm |
8.2.2 |
IMO class (Oil/Chemical Ship Type 1, 2 or 3): |
|
8.3 |
Number of slop tanks and total cubic capacity (98%): |
2 |
1,377.62 m3 |
8.3.1 |
Specify segregations which slops tanks belong to and their capacity with double valve: |
Seg#7: 1377.62 cbm |
8.3.2 |
Residual/Retention oil tank(s) capacity (98%), if applicable: |
93.415 m3 |
8.3.3 |
What is total SBT capacity and percentage of SDWT vessel can maintain? |
20,008.00 m3 |
45.579 % |
8.3.4 |
Does vessel meet the requirements of MARPOL Annex I Reg 18.2: |
Yes |
8.4 |
How many grades/products can vessel load/discharge with double valve segregation: |
7 |
8.4.1 |
State type of cargo containment (integral, independent, gravity or pressure tanks): |
|
8.5 |
Are there any cargo tank filling restrictions? If yes, specify number of slack tanks, max s.g., ullage restrictions etc.: |
Yes For High S.G. cargoes only
Max S.G of cargo =1.54
1 P&S 57.56 % Tank Height
2 P&S - 57.56 % Tank Height
3 P&S 57.56 % Tank Height
4 P&S 53.92 % Tank Height
5 P&S 53.92 % Tank Height
6 P&S 64.00 % Tank Height
Slop P&S 64.00 % Tank Height |
8.6 |
Max loading rate for homogenous cargo |
With VECS |
Without VECS |
Loaded per manifold connection: |
1,230 m3/hr |
1,230 m3/hr |
Loaded simultaneously through all manifolds: |
7,980 m3/hr |
7,980 m3/hr |
8.7 |
Is ship fitted with a Cargo Control Room (CCR): |
Yes |
8.8 |
Can tank innage / ullage be read from the CCR: |
Yes |
8.9 |
Is gauging system certified and calibrated? If no, specify which ones are not calibrated: |
Yes, NA |
|
What type of gauging system as per IBC 13.1 is fitted (Open/Restricted/Closed)? |
|
|
What type of fixed closed tank gauging system is fitted: |
Radar |
|
Is a tank overflow control system fitted? If yes, then state if system includes automatic closing of valves?: |
Yes, |
|
Are overfill (high) alarms fitted? If Yes, indicate whether to all tanks or partial: |
Yes, All |
8.9.1 |
Can cargo be transferred under closed loading conditions in accordance with ISGOTT 11.1.6.6? |
Yes |
8.9.2 |
Are cargo tanks fitted with multipoint gauging? If yes, specify type and locations: |
Yes, Tanktech UTI tapes through Vapour Locks |
8.10 |
Number of portable gauging units (example- MMC) on board: |
3 |
8.11 |
Is a Vapour Emission Control System (VECS) fitted? |
Yes |
8.12 |
Number/size of VECS manifolds (per side): |
2 |
300 mm |
8.13 |
Number / size / type of VECS reducers: |
16" x 12": 2
12" x 10": 1
12" x 8" : 1
12" x 6":1 |
8.14 |
State what type of venting system is fitted: |
HIGH VELOCITY P/V VALVES |
8.15 |
Total number / size of cargo manifold connections on each side: |
6 / 400 mm (Vessel's Presentation Flange is 16" which Incorporates 10 X 16" reducer. Vessel's Pipeline Size is 10". Vessel can remove 10 X16" reducer and connect the reducer of 12", 10" or 8" size) |
8.15.1 |
Does the vessel have a Common Line Manifold connection? If yes, describe: |
Common Line with double valve crossovers |
8.16 |
What type of valves are fitted at manifold: |
Butterfly |
8.17 |
What is the material/rating of the manifold: |
Mild Steel Reducers, Lines are SS / ANSI 150 PSI |
8.17.1 |
Does vessel comply with the latest edition of the OCIMF 'Recommendations for Oil Tanker Manifolds and Associated Equipment'? |
Yes |
8.18 |
Distance between cargo manifold centers: |
2,000 mm |
8.19 |
Distance ships rail to manifold: |
4,600 mm |
8.20 |
Distance manifold to ships side: |
4,600.00 mm |
8.21 |
Top of rail to center of manifold: |
741 mm |
8.22 |
Distance main deck to center of manifold: |
2,100.00 mm |
8.23 |
Spill tank grating to center of manifold: |
900 mm |
8.24 |
Manifold height above the waterline in normal ballast / at SDWT condition: |
13.288 m |
8.764 m |
8.25 |
Number / size / type of reducers: |
12 x 250/400mm (10/16") 6 x 250/300mm (10/12") 7 x 250/200mm (10/8") 1 x 300/200mm (12/8") 2 x 400/200mm (16/8") ANSI |
8.26 |
Is vessel fitted with a stern manifold? If yes, state size: |
No, 0 mm |
8.27 |
Cargo / slop tanks fitted with a cargo heating system? |
Type |
Coiled |
Material |
Cargo Tanks |
Steam, Deck mounted Heat Exchangers |
No |
SS |
Slop Tanks: |
Steam Heating coils |
Yes |
SS |
8.27.1 |
Is a Thermal Oil Heating system fitted? If yes, identify tanks?: |
No, |
8.28 |
Maximum temperature cargo can be loaded / maintained: |
70.0 °C / 158.0 °F |
60 °C / 140 °F |
8.28.1 |
Minimum temperature cargo can be loaded / maintained: |
|
|
8.29 |
Is an Inert Gas System (IGS) fitted / operational? |
Yes / Yes |
8.29.1 |
Is a Crude Oil Washing (COW) installation fitted / operational? |
Yes / Yes |
8.30 |
Is IGS supplied by flue gas, inert gas (IG) generator and/or nitrogen: |
IG Generator |
8.30.1 |
If nitrogen generator, specify the applicable flow rate for each of the designed purity modes: |
|
8.31 |
How many cargo pumps can be run simultaneously at full capacity: |
6 |
8.32 |
Pumps: |
No. |
Type |
Capacity |
At What Head (sg=1.0) |
Cargo Pumps: |
12 2 |
Deepwell centrifugal Submerged Centrigugal |
550 M3/HR 300 M3/HR |
125 Meters 125 Meters |
Cargo Eductors: |
0 |
N/A |
0 m3/hr |
0 m |
Stripping: |
12 |
Built in cargo stripping system |
550 m3/hr |
125 m |
8.33 |
Is at least one emergency portable cargo pump provided? |
Yes |
8.34 |
Is tank cleaning equipment fixed in cargo tanks? |
Yes |
8.35 |
Is portable tank cleaning equipment provided? |
Yes |
8.36 |
Tank washing pump capacity: |
400.00 m3/hr |
8.37 |
Is a washing water heater fitted? If yes is it operational and state max washing water temperature: |
Yes, Yes 85.00 °C |
8.38 |
What is the maximum number of machines that can be operated at their designed max pressure? |
4 |
8.39 |
Is vessel fitted with a remote cargo tank temperature monitoring system. If yes, is it operational? |
Yes, Yes |
8.40 |
Is vessel fitted with a remote cargo tank pressure monitoring system. If yes, is it operational? |
Yes, Yes |
8.41 |
Is vessel fitted with a cargo tank drier. If yes is it operational and state capacity: |
N/A, N/A, m3/hr |
8.42 |
Is vessel fitted with a cargo cooling system. If yes is it operational and state tanks applicable: |
N/A, N/A, |
8.43 |
Is steam available on deck? |
Yes |
|
9.1 |
Wires (on drums) |
No. |
Diameter |
Material |
Length |
Breaking Strength |
Forecastle: |
|
mm |
|
m |
MT |
Main deck fwd: |
|
mm |
|
m |
MT |
Main deck aft: |
|
mm |
|
m |
MT |
Poop deck: |
|
mm |
|
m |
MT |
9.2 |
Wire tails |
No. |
Diameter |
Material |
Length |
Breaking Strength |
Forecastle: |
|
mm |
|
m |
MT |
Main deck fwd: |
|
mm |
|
m |
MT |
Main deck aft: |
|
mm |
|
m |
MT |
Poop deck: |
|
mm |
|
m |
MT |
9.3 |
Ropes (on drums) |
No. |
Diameter |
Material |
Length |
Breaking Strength |
Forecastle: |
4 |
55 mm |
Signal B5 Yarn and High Performance Polyester |
220 m |
56.90 MT |
Main deck fwd: |
2 |
55 mm |
Signal B5 Yarn and High Performance Polyester |
220 m |
56.90 MT |
Main deck aft: |
2 |
55 mm |
Signal B5 Yarn and High Performance Polyester |
220 m |
56.90 MT |
Poop deck: |
4 |
55 mm |
Signal B5 Yarn and High Performance Polyester |
220 m |
56.90 MT |
9.4 |
Other lines |
No. |
Diameter |
Material |
Length |
Breaking Strength |
Forecastle: |
2 |
52 mm |
Polyproplene Polyester |
220 m |
56.90 MT |
Main deck fwd: |
1 |
55 mm |
Signal B5 Yarn and High Performance Polyester |
220 m |
56.90 MT |
Main deck aft: |
1 |
55 mm |
Signal B5 Yarn and High Performance Polyester |
220 m |
56.90 MT |
Poop deck: |
2 |
52 mm |
Polypropylene & Polyester |
220 m |
56.90 MT |
9.5 |
Winches |
No. |
No. Drums |
Motive Power |
Brake Capacity |
Type of Brake |
Forecastle: |
2 |
DOUBLE |
HYDRAULIC MOTOR |
45.50 MT |
Disc Brake |
Main deck fwd: |
1 |
DOUBLE |
HYDRAULIC MOTOR |
45.50 MT |
Disc Brake |
Main deck aft: |
1 |
DOUBLE |
HYDRAULIC MOTOR |
45.50 MT |
Disc Brake |
Poop deck: |
2 |
Double Drums |
Hydraulic |
45.50 MT |
Disc Brake |
9.6 |
Bitts, closed chocks/fairleads |
No. Bitts |
SWL Bitts |
No. Closed Chocks |
SWL Closed Chocks |
Forecastle: |
6 |
56.90 MT |
8 |
56.90 MT |
Main deck fwd: |
2 |
56.90 MT |
8 |
56.90 MT |
Main deck aft: |
6 |
56.90 MT |
8 |
56.90 MT |
Poop deck: |
6 |
56.90 MT |
14 |
56.90 MT |
9.7 |
Number of shackles on port / starboard cable: |
11 / 12 |
9.8 |
Type / SWL of Emergency Towing system forward: |
CHAIN STOPPER TONGUE TYPE |
200 MT |
9.9 |
Type / SWL of Emergency Towing system aft: |
STRONG POINT |
200 MT |
9.10.1 |
What is size of closed chock and/or fairleads of enclosed type on stern: |
600 X 450 |
9.10.2 |
What is SWL of closed chock and/or fairleads of enclosed type on stern: |
200 MT |
9.11 |
What is SWL of bollard on poop deck suitable for escort tug: |
200 MT |
9.12 |
Derrick / Crane description (Number, SWL and location): |
Cranes: 1 x 10 Tonnes Centre |
9.13 |
Accommodation ladder direction: |
Aft |
|
Does vessel have a portable gangway? If yes, state length: |
Yes |
12.135 m |
9.14 |
Does the vessel meet the recommendations in the latest edition of OCIMF 'Recommendations for Equipment Employed in the Bow Mooring of Conventional Tankers at Single Point Moorings (SPM)'? |
Yes |
9.15 |
If fitted, how many chain stoppers: |
1 |
9.16 |
State type / SWL of chain stopper(s): |
TONGUE TYPE |
200 MT |
9.17 |
What is the maximum size chain diameter the bow stopper(s) can handle: |
76.00 mm |
9.18 |
Distance between the bow fairlead and chain stopper/bracket: |
3.50 m |
9.19 |
Is bow chock and/or fairlead of enclosed type of OCIMF recommended size (600mm x 450mm)? If not, give details of size: |
Yes NA |
|
10.1 |
Speed |
Maximum |
Economical |
Ballast speed: |
14.00 Kts (WSNP) |
Kts (WSNP) (Contact Owners for Details) |
Laden speed: |
14.00 Kts (WSNP) |
12.00 Kts (WSNP) (Contact Owners for Details) |
10.2 |
What type of fuel is used for main propulsion / generating plant: |
|
VLSFO / LSMGO |
10.3 |
Type / Capacity of bunker tanks: |
Fuel Oil: 1,409.80 m3 Diesel Oil: 209.90 m3 Gas Oil: 220.40 m3 |
10.4 |
Is vessel fitted with fixed or controllable pitch propeller(s): |
Fixed |
10.5 |
Engines |
No |
Capacity |
Make/Type |
Main engine: |
1 |
7,260 Kw |
STX MAN6S50ME-B9.2 (NOX TIER II) |
Aux engine: |
3 |
960 Kw |
STX MAN B&W 6L23/30H |
Power packs: |
4 |
1,700 m3/hr |
Cumins KTA 19DM / Framo CCC500 - 4 |
Boilers: |
1 |
18.00 MT/Hr |
KANGRIM HEAVY INDUSTRIES = Type PB0301AS12 |
10.6 |
What is brake horse power of bow thruster (if fitted): |
No, 0 bhp |
10.7 |
What is brake horse power of stern thruster (if fitted): |
No, 0 bhp |
10.8 |
Main engine IMO NOx emission standard: |
Tier II |
10.9 |
Energy Efficiency Design Index (EEDI) rating number: |
4.6 grams-CO2/tonne-mile |
|
11.1 |
Does vessel comply with recommendations contained in OCIMF/ICS Ship To Ship Transfer Guide (Petroleum, Chemicals or Liquified Gas, as applicable)? |
Yes |
11.2 |
What is maximum outreach of cranes / derricks outboard of the ship's side: |
8.90 m |
11.3 |
Date/place of last STS operation: |
27 Jan 2023 / Alpha Zone, Argentina |
|
12.1 |
Last three cargoes / charterers / voyages (Last / 2nd Last / 3rd Last): |
|
12.2 |
Has vessel been involved in a pollution, grounding, serious casualty or collision incident during the past 12 months? If yes, full description: |
Pollution: No, None Grounding: No, None Casualty: No, None Repair: No, Collision: No, None |
12.3 |
Date and place of last Port State Control inspection: |
Feb 01, 2023 / San Lorenzo, Argentina |
12.4 |
Any outstanding deficiencies as reported by any Port State Control? If yes, provide details: |
No NA |
12.5 |
Recent Oil company inspections/screenings (To the best of owners knowledge and without guarantee of acceptance for future business)*:
*"Approvals" are not given by Oil Majors and ships are accepted for the voyage on a case by case basis. |
Contact owner for details. |
12.6 |
Date / place of last SIRE inspection: |
Feb 01, 2023 / San Lorenzo, Argentina |
12.6.1 |
Date / place of last CDI inspection: |
Not Applicable / Not Applicable |
12.7 |
Additional information relating to features of the ship or operational characteristics: |